Most compressor manufacturers require oil separators on all two stage compressors.
Refrigeration oil separator diagram. To minimize refrigerant condensation in the oil separator it should be installed as close to the compressor as possible preferably in a warm location. Based on the principle that oil and ammonia have different specific gravity the separator makes the mixed gas go through a vessel with large diameter during which oil sinks and is separated from the gas due to the change of flow rate and direction. Oil separators can also act as discharge mufflers to quiet compressor pulsation and vibration noises. Connect the discharge line from the compressor to the nipple labelled in.
Oil separators can also act as discharge mufflers to quiet compressor pulsation and vibration noises. Mount all oil separators vertically. An indicating sight glass and a hand shut off valve are installed in the oil return line. Oil separators are essential on low or ultra low temperature refrigeration systems and on large air conditioning systems up to 150 tons.
Worldwide delivery and most products on stock. Reticulated oil separators are widely used as part of refrigeration units with screw oil flooded compressors. The reticulated oil separator. Wanxiang is china ammonia oil separator manufacturer.
Combined oil separators are made as a combination of inertial reticulated and cyclone oil separators. Our refrigeration experts are available to assist you. If the oil separator is located slightly lower than the condenser install the line from the oil separator to the. How the helical oil separator functions.
The gas oil mixture is centrifugally forced along the spiral path of the helix causing heavier oil particles to spin to the perimeter where impingement with. The separator may be insulated to retard heat loss when the compressor stops. Oil separators and liquid separtors conform our high efficiency or high economy standard. Ref lithuania jsc represents manufacturers like danfoss we are the only one authorized danfoss representative in refrigeration and air conditioning area bitzer carel armacell frascold carrier refco and many others factories and suppliers.
Install the oil separator in a location where it is higher than the condenser. Oil separators are essential on low or ultra low temperature refrigeration systems and on large air conditioning systems up to 150 tons. Prevent the migration of liquid refrigerant back into the oil separator shell during off cycles by one of the following recommendations. Upon separator entry refrigerant gas containing oil in aerosol form encounters the leading edge of the helical flighting.
A chart of special models below are for use for r 410a refrigerant.